dryer heating element reads 10 ohms - Axtarish в Google
9 янв. 2007 г. · Remove wire leads from heating element, VOM shows 10.0 Ohms across it. This means element not broken/open, but I have no idea if that's an in-spec value.
I have a dryer that is not heating, I already tested the element and it's good @ 10 ohms ... You would need to test voltage at the element with dryer running.
4 окт. 2018 г. · It is labeled 5400 watt, 240 volt. That should ohm out to about 22 ohms, 18 at 80% rule. A Youtube video says it should ohm about 16. I am getting 10 ohms.
18 сент. 2024 г. · 10 ohms on a 240v supply will give you 24amps. Eg 240v / 18ohms = 13amps roughly what you'd expect from a kettle.
19 окт. 2023 г. · The heating element itself should also read about 15 ohms. The high limit, thermostat, and thermal cut-off fuse should read about 0. The last ...
The ideal reading for a tumble dryer element is between 20 and 50 ohms - so any reading significantly outside of this range means the element is faulty and ...
12 дек. 2014 г. · If your dryer is not heating then you should test the heating element ... on how to test your dryers heating element using a multimeter or ohm ...
3 мая 2020 г. · Take the red and black wires off the element and measure resistance. You should get in the neighborhood of 10 ohms. To replace the element ...