9 мая 2007 г. · Code 5 lead can be laid in bays up to 2000mm long between steps/drips. Code 8 can be laid in bays up to 3000mm long.
4 мар. 2011 г. · The best job, by far, would be to do it in lead. 1 piece of Code 7 lead will be fine for 2.6lm, 1:80 fall. Maybe the more expensive option.
17 окт. 2008 г. · If using code 5 sheet lead the max length of any one piece should not exceed 2 m. I.5m if code 4 is used. It look as if the sheet lead has ...
20 февр. 2011 г. · The width of the box gutter will be determined by the pitch of the two roofs but ideally you would want to be getting 600mm + to stop it blocking with leaves.
17 дек. 2013 г. · It is a valley and a traditional way to deal with it is a lead gutter to falls that is formed with steps in it to suit the normal maximum length ...
4 окт. 2022 г. · The length of each gutter is 5m. Going by what has been said on here that seems incorrect. Looking online can't really see what the max length ...
16 авг. 2003 г. · All the literature (from Wicks and Calder group) insists that lengths should be no longer than 1.5m, which means that I will end up with 8 ...
30 авг. 2010 г. · Lead may be problematic as it will need to be in maximum 1500mm ... Hi, can use lead, but to allow for the length you would require a ...
28 авг. 2012 г. · 5m will expand/contract by 4.2mm. If the lead is fixed in the middle (or even unfixed) it allows the ends to expand/contract by 2mm. I think ...