1) A 100 amp feeder circuit at a distance of 100 ft from the main electrical panel to the sub-panel requires either 2 AWG copper or 1 AWG aluminum for the 2 hot wires and the neutral wire. The 4th wire, equipment grounding conductor needs to be sized as either . 8 AWG copper or 6 AWG aluminum for 100 amps.
According to NEC 310.15(B)16, the suitable wire size for a 100A breaker in the main panel or subpanel is #4 AWG copper or #2 AWG aluminum having a distance of ...
23 мар. 2023 г. · The ground wire size for 100 Amp service is different. You would typically use 8 AWG copper grounding wire or 6 AWG aluminum grounding wire.
Most panels require #2 AWG wire for 100-amp service. You'll need to use #4 AWG wire if the distance between the utility and breaker panel is less than 50 feet.
100amps will require #3 copper and a #8 copper ground wire. Since it is a sub panel, 4 wires are required. 2 hots, a neutral, and a ground wire. Customer.
8 апр. 2024 г. · 100 Amp Sub-Panel Wire Gauge · 1 cable will take you about 145 feet before you will see a 3% voltage drop at 100Amps.
1 июл. 2024 г. · The 100-ampere wire size calculator will assist you in choosing the proper wire size for your next equipment installation.
15 апр. 2022 г. · 1 1/4” pvc conduit is the correct size for this run if done in aluminum xhhw wire. Though I would personally use 1 1/2” pvc in case you want to ...